Published: Vol 5, Iss 20, Oct 5, 2015 DOI: 10.21769/BioProtoc.1615 Views: 8057
Reviewed by: Savita NairAnonymous reviewer(s)
Protocol Collections
Comprehensive collections of detailed, peer-reviewed protocols focusing on specific topics
Related protocols
A Surface Plasmon Resonance Method to Study HCV NS5B Inhibitors
Melanie Wong and Giuseppe A. Papalia
Feb 20, 2014 8855 Views
Large-scale Purification of Type III Toxin-antitoxin Ribonucleoprotein Complex and its Components from Escherichia coli for Biophysical Studies
Parthasarathy Manikandan [...] Mahavir Singh
Jul 5, 2023 1027 Views
Flotation Assay With Fluorescence Readout to Study Membrane Association of the Enteroviral Peripheral Membrane Protein 2C
Kasturika Shankar [...] Lars-Anders Carlson
Apr 5, 2025 735 Views
Abstract
Kinetic analysis of antibodies is one of the important studies for characterization of antibodies and screening of ligands. In our recent study (Ingale et al., 2014), we compared the antigenic profiles and binding characteristics of four HIV-1 envelope glycoprotein (Env) core immunogens using multiple monoclonal antibodies by Bio-Layer Light Interferometry (BLI). This technology enables real-time analysis of interactions on the surface of a fiber optic biosensor by accurately measuring kinetic constants such as Ka, Kd, and KD in a 96-well format.
Materials and Reagents
Equipment
Software
Procedure
Biosensors are tips coated with proprietary biocompatible matrix that can bind to Fc region of human immunoglobulin with minimal non-specific binding. In a separate black bottom plate, the biosensors were hydrated in 200 μl PBS for 10 min at room temperature prior to the experiment. The sample plate was generated according to the template shown in Figure 1. The buffer wells were filled with 200 μl PBS. Selected monoclonal antibodies were diluted to 5 μg/ml in PBS and dispensed at a volume of 200 μl into each well of the loading column as indicated in the template. The H1 well was filled with 200 μl PBS. The analyte (HIV envelope core glycoprotein is used in the example shown in Figure 1) was 2-fold serially diluted in PBS starting from 1 μM to 31.25 nM in a separate plate and transferred in a 200 μl volume in the “association column” of the template as shown (Figure 1). The sensor plate (plate with bio-sensors) and sample plate (plate with other reagents, as shown in Figure 1) were then inserted into the Octet Red machine and a basic kinetic measurement experiment was performed as follows:
Acknowledgments
This protocol was previously used in Ingale et al. (2014).
References
Article Information
Copyright
© 2015 The Authors; exclusive licensee Bio-protocol LLC.
How to cite
Ingale, J. and Wyatt, R. T. (2015). Kinetic Analysis of Monoclonal Antibody Binding to HIV-1 gp120-derived Hyperglycosylated Cores. Bio-protocol 5(20): e1615. DOI: 10.21769/BioProtoc.1615.
Category
Immunology > Antibody analysis > Antibody-antigen interaction
Microbiology > Microbial biochemistry > Protein
Do you have any questions about this protocol?
Post your question to gather feedback from the community. We will also invite the authors of this article to respond.
Tips for asking effective questions
+ Description
Write a detailed description. Include all information that will help others answer your question including experimental processes, conditions, and relevant images.
Share
Bluesky
X
Copy link